Assessing Rapid Variability in Atmospheric Apparent Optical Depth with an Array Spectrometer System
A method for determining rapid variations in atmospheric optical depth is proposed. The method is based upon computation of the ratio between close-time spectral measurements of solar direct flux. Use of the ratio avoids the need for absolute calibration of the instruments and minimizes the effects of changes in instrumental conditions (such as temperature or mechanical adjustments) and in air mass. The technique has been applied to some campaigns of measurement for sky conditions ranging from clear skies to scattered-to-broken cloudiness, performed at high frequency (~1Hz) with a system of three array spectrometers, capable of performing very rapid spectral acquisitions, [...]
A method for determining rapid variations in atmospheric optical depth is proposed. The method is based upon [...]